RUST-OLEUM CORP -- STOPS RUST BRAND PROTECTIVE COATINGS, V7715 -- 8010-00N023210
=====================  Product Identification  =====================

Product ID:STOPS RUST BRAND PROTECTIVE COATINGS, V7715
MSDS Date:11/29/1989
FSC:8010
NIIN:00N023210
=== Responsible Party ===
Company Name:RUST-OLEUM CORP
Address:11 HAWTHORN PARKWAY
City:VERNON HILLS
State:IL
ZIP:60061
Country:US
Info Phone Num:708-367-7700
Emergency Phone Num:708-367-7700
Preparer's Name:J.C.O.
CAGE:08882
=== Contractor Identification ===
Company Name:RUST-OLEUM CORP
Address:11 HAWTHORN PARKWAY
Box:City:VERNON HILLS
State:IL
ZIP:60061-1583
Country:US
Phone:847-367-7700
CAGE:08882

=============  Composition/Information on Ingredients  =============

Ingred Name:STODDARD SOLVENT; (MINERAL SPIRITS). VP: 2 @ 20C.
CAS:8052-41-3
RTECS #:WJ8925000
Fraction by Wt: 30-50%
OSHA PEL:500 PPM
ACGIH TLV:100 PPM; 9293

Ingred Name:PROPYLENE GLYCOL MONOMETHYL ETHER. VP: 10.9 @ 20C.
CAS:107-98-2
RTECS #:UB7700000
Fraction by Wt: 0-4%
OSHA PEL:100 PPM;150 PPM STEL
ACGIH TLV:100 PPM;150 PPM STEL

Ingred Name:XYLENES (O-,M-,P- ISOMERS); (XYLENE). VP: 9.5 @ 20C.
CAS:1330-20-7
RTECS #:ZE2100000
Fraction by Wt: 0-1%
OSHA PEL:100 PPM;150 PPM STEL
ACGIH TLV:100 PPM;150 PPM STEL
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:ACUTE:INHAL:HARMFUL IF INHALED. MAY
    AFFECT BRAIN/NERVS SYS CAUSING DIZZ, HDCH/NAUSEA. RPTD OVEREXP MAY
    LEAD PROGRESSIVELY TO STAGG GAIT, CONFUSION, UNCON/COMA. CAUSES
    NOSE & THROAT IRRIT. SKIN/EYE:CAU SES IRRIT WHICH MAY LEAD TO DERM
    W/RPTDOVEREXP. INGEST: MAY CAUSE GI IRRIT, NAUSEA, VOMIT & DIARR.
    (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: CHRONIC: REPORTS HAVE SHOWN REPEATED
    AND PROLONGED OCCUPATIONAL OVEREXPOSURE TO SOLVENTS WITH PERMANENT
    BRAIN AND NERVOUS SYSTEM DAMAGE.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

=======================  First Aid Measures  =======================

First Aid:INHAL: REMOVE FROM EXPOS, RESTORE BRTHG & NOTIFY MD. EYES:
    FLUSH IMMED W/LG AMTS OF WATER FOR AT LEAST 15 MINUTES. NOTIFY MD.
    SKIN: WASH AFFECTED AREA W/SOAP & WATER, REMOVE CONTAMD CLTHG &
    WASH BEFOR E REUSE. INGEST: DO NOT INDUCE VOMIT. KEEP PERSON WARM,
    QUIET & GET MEDICAL ATTENTION. ASPIRATION OF THIS MATERIAL INTO THE
    LUNGS CAN CAUSE CHEMICAL PNEUMONITIS WHICH CAN BE FATAL.

=====================  Fire Fighting Measures  =====================

Flash Point:104F,40C
Extinguishing Media:NFPA CLASS B EXTINGUISHERS (CARBON DIOXIDE, DRY
    CHEMICAL OR FOAM).
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP
    . WATER SPRAY MAY BE INEFFECTIVE. WATER MAY BE USED TO COOL CLSD
    CNTNRS TO PVNT PRESS BUILD-UP (SUPP DATA)
Unusual Fire/Explosion Hazard:KEEP CNTNRS TIGHTLY CLSD. ISOLATE FROM
    HEAT, ELEC EQUIP, SPKS & OPEN FLAME. CLSD CNTNRS MAY EXPLODE WHEN
    EXPOSED TO EXTREME HEAT. DO NOT APPLY TO HOT SURFACES.

==================  Accidental Release Measures  ==================

Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION, VENTILATE AREA
    AND REMOVE WITH INERT ABSORBENT AND NON-SPARKING TOOLS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:DO NOT STORE ABOVE 120F. STORE LARGE
    QUANTITIES IN BUILDINGS DESIGNED & PROTECTED FOR STORAGE OF NFPA
    CLASS II COMBUSTIBLE LIQUIDS.
Other Precautions:CONTAINERS SHOULD BE GROUNDED WHEN POURING. EMPTY
    CONTAINERS MAY BE HAZARDOUS.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:USE NIOSH/MSHA APPROVED CHEMICAL CARTRIDGE
    RESPIRATOR (TC23C) TO REMOVE SOLID AIRBORNE PARTICLES OF OVERSPRAY
    AND ORGANIC VAPORS DURING SPRAY APPLICATION. INCONFINED AREAS: USE
    NIOSH/MSHA APPROVED SUP PLIED-AIR RESPIRATORS OR HOODS (TC19C).
Ventilation:PROVIDE GEN DILUTION/LOCAL EXHAUST VENT IN VOL & PATTERN TO
    KEEP TLV OF HAZARDOUS INGREDIENTS BELOW ACCEPTABLE LIMIT.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
% VOLAT: 32-50 (BY WEIGHT). FIRE FIGHT PROC: AND POSSIBLE AUTOIGNITION
    OR EXPLOSION. IF WATER IS USED, FOG NOZZLES ARE PREFERRED.

==================  Physical/Chemical Properties  ==================

HCC:F4
Boiling Pt:B.P. Text:307F,153C
Vapor Pres:SEE ING
Vapor Density:HVR/AIR
Evaporation Rate & Reference:SLOWER (ETHER=1)
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:SUPDAT

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:BY OPEN FLAME: CO & CO*2.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE OF ACCORDING TO LOCAL, STATE AND FEDERAL
    REGULATIONS. DO NOT INCINERATE CLOSED CONTAINERS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.